Catalyst 5000 Family

Placement

Rack-mounted, front or back (standard 19 in. [48.26 cm] rack)

Center-mount for 23 in. (58.42 cm), two-post racks are available for 5000 chassis

 

Switching backplane

1.2 Gbps (Cisco Catalyst 5000 and 5002):

 

Memory

4 MB Flash memory (all supervisor engine I models)

8 MB Flash memory (all supervisor engine II models, III F, II G, and III G)

8 MB Flash memory + PC Card Flash support (all supervisor engine III models)

4 or 20 MB DRAM (supervisor engine I)

16 or 32 MB DRAM (supervisor engine II)

32 MB DRAM (supervisor engine III, III F, II G, and III G)

128 KB NVRAM (supervisor engine I)

256 KB NVRAM (supervisor engine II)

512 KB NVRAM (supervisor III, III F, II G and III G)

 

Interfaces

Supervisor Engine I console: DB-25 (female)

Supervisor Engine II console: DB-25 (female)

Supervisor Engine III, III F console: RJ-45 (female)

Supervisor Engine II G, III G console: RJ-45 (female)

Supervisor Engine I 100Base-TX uplink: RJ-45 (female), 2 interfaces

Supervisor Engine I 100Base-FX uplink: MMF SC or SMF SC, 2 interfaces

Supervisor Engine II 100 Base-TX uplink: RJ-45 (female), MII

Supervisor Engine II 100 Base-FX uplink: MMF SC, SMF SC

Supervisor Engine III 10/100Base-TX uplink: RJ-45 (female), 2 interfaces

Supervisor Engine III, II G10/100Base-TX uplink: RJ-45 (female), 4 interfaces

Supervisor Engine III 100Base-FX uplink: MMF SC or SMF SC, 2 interfaces

Supervisor Engine III, II G 100Base-FX uplink: MMF MT-RJ, 4 interfaces

Supervisor Engine III, II G 1000Base-SX uplink: MMF SC, 2 interfaces

Supervisor Engine III, II G 1000Base-LX uplink: SMF SC, 2 interfaces

Group Switched 10Base-T: RJ-21 (female), 48 interfaces

Switched 10Base-T: RJ-21 (female), 48 or 24 interfaces

Switched 10Base-T: RJ-45 (female), 24 interfaces

Switched 10Base-FL: SC (female), 12 interfaces

Switched 10Base-FL: MT-RJ (female), 24 interfaces

Group Switched 100Base-TX: RJ-45 (female), 24 interfaces

Switched 10/100Base-TX: RJ-45 (female), 24 or 12 interfaces

Switched 10/100Base-TX:RJ-21 (female), 36 interfaces

Switched 100Base-FX: MMF SC, 12 interfaces

Switched 100Base-FX: MMF SC, SMF SC, 12 interfaces (6 MMF interfaces plus 6 SMF interfaces)

Switched 100Base-FX:MT-RJ (female), 24 interfaces

Fast Ether Channel 10/100Base-TX: RJ-45 (female), 24 or 12 interfaces

Fast Ether Channel 100Base-FX: MMF SC, 12 interfaces

Gigabit Ethernet: GBIC SX or LX, 3 interfaces

Gigabit EtherChannel: GBIC SX or LX, 9 interfaces

Switched Token Ring: RJ-45 copper UTP/STP (female), 16 ports

Switched Token Ring: MMF 62.5-micron fiber, 16 ports

ATM LANE/MPOA Uplink: OC-3 or OC-12: SMF SC, or MMF SC, 1 interface (dual-PHY)

ATM LAN Emulation: UTP RJ-45, MMF SC, SMF SC, dual PHY

CDDI: RJ-45 (female), 1 interface

FDDI: MMF MIC, SMF ST, 1 interface

Optical bypass switch connector: 6-pin mini-DIN

 

Port adapter modules (for Cisco Catalyst 5500)

ATM OC-3: SONET STS3c/SDH STM1, MMF SC or SMF SC, RJ-45, 4 ports

ATM OC-12: SONET STS12c/STM4c, SMF SC, 1 port DS-3: 75-ohm coaxial

BNC, 2 or 4 T3 DS3 ports

E-3: 75-ohm coaxial BNC, 2 E3 ports

T1/E1 ATM trunk: RJ-48, 4 ports, balanced or unbalanced

T1/E1 circuit emulation: RJ-48, 4 ports, balanced or unbalanced

25 Mbps ATM: Telco Cable 96-pin, 12 ATM25 ports

 

Duplex

10 Mbps Ethernet: Full or half duplex

100 Mbps Fast Ethernet: Full or half duplex

10/100 Mbps Fast Ethernet: Auto-negotiated speed and duplex

1000 Mbps Gigabit Ethernet: Full or half duplex

Token Ring copper: full or half duplex

Token Ring fiber: half duplex

FDDI: Half duplex

ATM: Full duplex

Group switched 10Base-T and 100Base-TX: Half duplex

 

Network Management

CiscoWorks for Switched Internetworks GUI management including the following:

CiscoView

VlanDirector

Traffic Director

User Tracking

ATMDirector

Cisco Discovery Protocol

VLAN Trunk Protocol

SNMP agent v1 (RFC 1155-1157)

SNMP MIB II (RFC 1213)

RMON (4 groups)

RMON/RMON2 (all groups) with the optional Network Analysis Module (WS-X5380)

Ethernet MIB (RFC 1643)

Ethernet repeater MIB (RFC 1516)

Interface Table (RFC 1573)

Bridge MIB (RFC 1493)

Token Ring MIB (RFC 1748)

Source-Route Bridge MIB (RFC 1525)

Cisco Stack MIB Extensions (Token Ring group)

RMON Token Ring Extensions (RFC 1513)

Token Ring extensions for Statistics, History, Alarms, and Events groups

Ring Station Order Group

Ring Station Control Table

FDDI MIB (RFC 1512)

SMT 7.3 (RFC 1285)

AToM MIB (RFC 1695)

ILMI MIB

Cisco Workgroup MIB

LEC MIB (ATM Forum LANE v1.0)

Cisco LECS, LES/BUS MIB

Telnet, TFTP, BOOTP, LAN Emulation client, RFC 1577 Classical IP over ATM client: management access

E-SPAN

Text-based command-line interface based on familiar router interface

Standard Cisco IOS security capabilities: passwords and TACACS

 

Standard protocols

Ethernet: IEEE 802.3, 10Base-T, and 10Base-FL

Fast Ethernet: IEEE 802.3u, 100Base-TX, 100Base-FX

Gigabit Ethernet: IEEE 802.3z

Token Ring: IEEE 802.5r, IEEE 802.5j

FDDI: ISO 9314-1 FDDI PHY standard; ISO 9314-3 FDDI PMD standard; CDDI TP-PMD standard; ANSI FDDI X3T9.5 SMT 7.3

ATM Forum: 3.1 UNI Specification, Q.2931 signaling protocols, ATM Forum LANE v1.0, LUNI v.2.0, MPOA

 

Maximum cabling distances

10Base-T Ethernet: Category 5 UTP, 328 ft. (100 m)

10Base-FL Ethernet: 62.5/125-micron fiber, 1.24 miles (2 km)

100Base-TX Fast Ethernet: Category 5 UTP, 328 ft (100 m)

10/100Base-TX Fast Ethernet: Category 5 UTP, 328 ft (100 m)

100Base-FX Fast Ethernet: 62.5/125 multimode fiber, 0.248 mile (400 m) half duplex, 1.24 miles (2 km) full duplex or 8.7/125 single-mode fiber, 6.2 miles (10 km), full or half duplex

1000Base-SX Gigabit Ethernet: 62.5/125 MMF, 0.171 miles (275 m); 50/125 MMF, 0.341 miles (550m)

1000Base-LX Gigabit Ethernet: 62.5/125 MMF, 0.341 miles (550m); 50/125 MMF, 0.341 miles (550m); 9/125 or 10/125 SMF, 6.2 miles (10km)

1000Base-ZX Gigabit Ethernet: 10/125 SMF, up to 62 miles (100km) with dispersion shifted single mode fiber

4 Mbps Token Ring 150-ohm STP: Types 1, 1a, 2, 2a, 2460 ft (750 m); Type 8, 1234 ft (376 m); Type 9, 1640 ft (500 m)

4 Mbps Token Ring 100-ohm UTP: Category 3, 820 ft (250 m); Category 4, 1148 ft (350 m); Category 5, 1148 ft (350 m)

16 Mbps Token Ring: 150-ohm STP Types 1, 1a, 2, 2a, 952 ft (290 m); Type 8, 480 ft (146 m); Type 9, 656 ft (200 m)

16 Mbps Token Ring 100-ohm UTP: Category 3, 328 ft (100 m); Category 4, 656 ft (200 m); Category 5, 656 ft (200 m)

CDDI: Category 5 UTP, 328 ft (100 m)

FDDI: 62.5/125 multimode fiber, 1.24 miles (2 km) or 8.7/125 single-mode fiber,

6.2 miles (10 km)

ATM LAN emulation module UTP: Category 5 UTP, 328 ft (100 m)

ATM Uplink module MMF: 62.5/125-micron fiber, 1.24 miles (2 km)

ATM Uplink module SMF: 8.7/125-micron fiber, 6.2 miles (10 km)

 

Fiber-optical specifications

Multimode specifications for modules WS-X5006, WS-X5011,WS-X5236-FX-MT, WS-X5201R, WS-X5114=, WS-X5101, WS-X5158, WS-X5167,WS-X5031, and WS-X5506:

  • Transmitter output power: -19 to -14 dBm

  • Receiver sensitivity: -32.5 to -14 dBm

  • Wavelength: 850 to 1360 nm

  • Optical source: LED

  • Maximum span: 1.24 miles (2 km)

Single-mode specifications for modules WS-X5237-FX-MT, WS-X5005, WS-X5157, WS-X5168, WS-X5114=, WS-X5154, and WS-X5505:

  • Transmitter output power: -14 to -8 dBm

  • Receiver sensitivity: -32.5 to -8 dBm

  • Wavelength: 1261 to 1360 nm

  • Optical source: Laser

  • Maximum span: 6.2 miles (10 km)

Single-mode specifications for module WS-X5104:

  • Transmitter output power: -4.0 to -7.0 dBm

  • Receiver sensitivity: -33 to -14 dBm

  • Optical source: Laser

  • Maximum span: 18.63 miles (30 km)

 

LEDs

Status LED on each module shows successful completion, minor and major failure of power-up diagnostics

Link Good LED shows status of any interface

Switch Load LEDs show backplane utilization

MII = media-independent interface

FE = Fast Ethernet

MMF = multimode fiber

SMF = single-mode fiber

dBm = decibels per milliwatt

 

AC power requirements

Cisco Catalyst 5500

8.0 Amps at 230 VAC, 50 Hz

16 Amps at 115 VAC, 60 Hz

Power consumption: 1100W

kVA = 1.84

 

DC power requirements

Cisco Catalyst 5500

-40.5 VDC to -72 VDC continuous

Typical range (U.S. and Canada)

-48 VDC (nominal)

-54 VDC (high)

-42 VDC (low)

Typical range (international)

-60 VDC (nominal)

-72 VDC (high)

-52 VDC (low)

 

Temperature

Operating: 32 to 104°F (0 to 40°C)

Storage: -40 to 167°F (-40 to 75°C)

 

Humidity

10 to 90%, noncondensing

 

MTBF

7 years for system configuration

 

Dimensions (H x W x D)

25.25 x 17.3 x 18.25 in. (64.14 x 43.9 x 46.36 cm)

 

Weight

Minimum: 70 lb (31.7 kg)

Maximum: 160 lb (72.5 kg)

 

Safety certifications

UL 1950

EN 60950

CSA-C22.2 No. 950

IEC 950

TS 001

AS/NZS 3260

 

Electromagnetic emissions certifications

Over UTP:

FCC Class A (47 CFR, Part 15)

ICES -003 Class A

EN 55022 Class A

CISPR22 Class A

AS/NZS 3548 Class A

VCCI Class A

Over FTP:

EN 55022 Class B

CISPR22 Class B

AS/NZS 3548 Class B

VCCI Class B

 
Home
Store
Used Network Equipment
Used Cisco
Used Sun
Used Extreme Networks
Used Foundry
Used Juniper
Reference
Cisco and Networking
Phones and Phone Switches
Racks and Cables
Asset Remarketing
Computer Liquidation
Computer Liquidator
Our Market
Contact Us
 
Home   |   Network Equipment   |   Cisco   |   Sun   |   Extreme Networks   |   
Foundry   |   Juniper   |   Asset Remarketing   |   Computer Liquidation   |   Computer Liquidator